Document ID
APT-DS-SLVS-RX-0001
Revision
2.1
IP version
3.4.1
Release date
November 2026
Chapter 5: Example Designs and Software

5.4Bring-up flow

  1. Recreate the projectRun the example design's Tcl script in Vivado. It adds the IP repository, builds the block design and applies the constraints.
  2. Choose the buildIn the IP GUI set Lanes and Payload protection to match the sensor mode, pick the Output, and size the Output FIFO for the longest line (NATIVE) or the longest sink stall (AXI4S). Turn the Embedded data output on if the application reads the sensor’s metadata. Use the GT Wizard PHY for Baud Grade 3, or either PHY for Baud Grade 1 and 2.
  3. Build and exportGenerate the bitstream and export the hardware platform for Vitis.
  4. Build the applicationCreate the Vitis platform and application, add the example sources and the driver, and select the sensor mode.
  5. RunProgram the board. The console prints the IP version and build, then starts the sensor.
  6. Check the linkThe frame counter rises with every frame, the delivered height matches the image and the header CRC error count stays at 0. A rising header error count points at lane order, polarity or signal integrity.