Document ID
APT-DS-SLVS-RX-0001
Revision
2.1
IP version
3.4.1
Release date
November 2026
Chapter 3: Interfaces and Timing

3.1IP customization parameters

All parameters are set when the IP is generated in Vivado. Software reads them back from the HWCFG register, so one driver serves every build.

Table 3-1.IP customization parameters.
GUI fieldParameterValuesDefaultDescription
LanesLANE_NUM1, 2, 4, 6, 84SLVS-EC lane count; must match the sensor's Lane Num.
Payload protectionECC_SELCRC (0), ECC Reed-Solomon (1)CRCBuilds the CRC32 checker or the Reed-Solomon corrector; must match the sensor mode.
OutputOUT_MODEAXI4S (1), NATIVE (0)NATIVEVideo interface; only the ports of the selected output are shown.
Output FIFO depth (words)OUT_FIFO_DEPTH128 to 16384, powers of 22048NATIVE line buffer or AXI4S FIFO.
Embedded data outputEBD_OUTOff (0), On (1)OffBuilds the embedded data stream M_AXIS_EBD with its clock, reset and FIFO, next to either video output.
EBD FIFO depth (words)EBD_FIFO_DEPTH32 to 16384, powers of 21024Embedded data FIFO, shown with Embedded data output on.

From a block design script:

set_property -dict [list \
    CONFIG.LANE_NUM       {2} \
    CONFIG.ECC_SEL        {0} \
    CONFIG.OUT_MODE       {1} \
    CONFIG.OUT_FIFO_DEPTH {2048} \
    CONFIG.EBD_OUT        {1} \
    CONFIG.EBD_FIFO_DEPTH {1024} \
] [get_bd_cells slvs_ec_rx_0]

The PHY is delivered set up for your sensor mode and board; there is no transceiver configuration to do.