Link layer
- Receive link layer of the SLVS-EC Interface Standard v2.0 (JIIA EVI-001-2019)
- 1, 2, 4, 6 or 8 lanes, selected at build time
- Baud Grade 1, 2 and 3: up to 5.0 Gb/s per lane, 40 Gb/s aggregate
- Bundled PHY: APT-SLVS-EC GT Wizard on GTH or GTY up to Baud Grade 3, or SLVS-EC HP I/O up to Baud Grade 2
- Triple packet header, each copy checked by CRC16; the first good copy is used
- Lane merge, byte realignment and Pad Code removal across all lanes
- Frame Start, Frame End and Line Valid decoding into whole frames
Payload integrity
- CRC build: payload CRC32 footer check
- ECC build: Reed-Solomon payload correction, ECC Option 1 (1 byte per block) or Option 2 (up to 2 bytes per block)
- Header CRC counters for bad copies and lost headers; payload CRC32 counter with the Line Number of the last failing line
- Corrected-symbol counters, per frame and running
- Uncorrectable blocks passed on unchanged and counted, never hidden
Video output
- AXI4-Stream video (tuser = start of frame, tlast = end of line) on an independent clock
- Native video with vsync, hsync, hblank, vblank and gap-free active lines
- RAW8, RAW10, RAW12, RAW14 and RAW16, selectable at run time
- 2 x LANE_NUM pixels per beat in MSB-justified 16-bit containers
- Optional embedded data output: the sensor’s metadata lines on their own AXI4-Stream, clock and FIFO, with either video output
- Crop by line skip, width and height, updated frame by frame while streaming
- Clean recovery from output overflow without a reset
Integration
- AXI4-Lite control with ID, version and build discovery
- Lane, register and stream clocks fully independent; no user CDC constraints
- Packaged for Vivado IP Integrator with a customization GUI
- Software driver for setup and control on MicroBlaze, Zynq-7000 and Zynq UltraScale+ MPSoC
- Example designs for Zynq UltraScale+ MPSoC, Kria K26 and Kintex UltraScale+