The frame grabber discovers the camera at a low speed and moves it to the operating speed with
ConnectionConfig. When firmware has acknowledged that write, it writes the new speed code and
CXP_RATE_TRANS.APPLY. The core then
- Rewrites the transmitterDRP writes to the channel and common PLL for the new rate, from tables built into the core for each transceiver option.
- Resets itA PLL and datapath reset on
reset_TX_PLL, held at least the minimum time. - Waits for itThe transmitter must take the reset and report reset done within the timeouts set in the IP GUI; the core retries the reset up to the configured number of times.
- ReportsTX_READY when the transmitter is back, or RATE_ERR with an error code in
CXP_STATUS[15:14].
A request is taken in any state, also with the transmitter down, and a request during a change runs next (newest wins). The core refuses rate code 7 with SLVERR.
| Code | Meaning | What to check |
|---|---|---|
| 1 | DRP no answer | The transceiver did not answer the DRP writes in time. The transceiver is not reset; check the DRP clock and connection. |
| 2 | Reset not acknowledged | The transceiver wrapper never took the PLL and datapath reset: reset_TX_PLL is not connected to it. |
| 3 | Reset done never back | transmitter reset done did not return after the retries: the PLL is not locking (reference clock, or the board). |